Unit 4: Replacement Procedures
SATO D508/D512 Service Manual Page 4-5
FUSE REPLACEMENT
1 Turn the printer OFF and disconnect the power supply cord.
2 Remove the base cover from the housing cover to access the fuse.
3 Locate fuse (1), (See Figure 4-4) on the main circuit board (2).
4 Detach the defective fuse (1) from the metal holders (3).
5 Attach a replacement fuse (1) to the metal holders (3) on the main circuit board (2).
6 Attach base cover to the housing cover.
7 Load some media, and run some tests to confirm proper function.
Figure 4-4, Fuse Replacement
1
2
3